 Inrush current Rush current will flow into power supply unit once city utility is applied.
 Output voltage accuracy Power supply unit output voltage volume is under rated load condition.
 Ripple and Noise Ripple voltage will be caused by input electrolytic capacitor charging and discharging. And power supply unit internal circuit of P.W.M (Pulse Width Modulation) turns switching MOSFET on and off to cause some voltage spike. Both ripple voltage and spike voltage affect power supply unit voltage various.
 Turn on delay time Duration of AC applies to power supply unit, and power supply unit output voltage reaches to 90% of rated voltage.
 Hold up time Duration of power supply unit output voltage drops down to 90% of rated voltage from AC removal.
 Transfer efficiency Percentage of output power divides by input power. It means Pout / Pin * 100%
 Load regulation Output voltage volume varies when it is light load, half load or full load.
 Input line regulation Output voltage volume change is affected by input AC voltage vary.
 Output overshoot Power supply unit output voltage overshoot following a rising edge when AC is applied.
 Rising time Duration of power supply unit output voltage rises from 10 % to 90%.
 Falling time Duration of power supply unit output voltage falls from 90 % to 10%.
 Dynamic load Power supply unit output voltage varies under dynamic load (load value is shown on specification).
 Peak load Maximum load capacity from power supply unit in specified duration.
 Rated load Rated load capacity shows on the label of power supply unit. Power supply unit must guarantee its performance and reliability to meet its specification.
 Over voltage protection In case power supply unit output voltage exceeds its rated output voltage range and reaches specified voltage, power supply unit must turn off the output to protect system.
 Over current protection When voltage volume from power supply unit exceeds system default set up due to the system damages, power supply unit must turn off its output to against system damaged.
 Operating temperature range Under specified temperature range, power supply unit must work normally and its performance must be guaranteed.
 Storage temperature range Under specified storage temperature range, power supply unit shape should not be changed.
 Operating humidity range Under specified humidity range, power supply unit must work normally and its performance must be guaranteed.
 Mean Time Between Fault(MTBF) Mean time between fault of power supply unit under normal operating.
 De-rating Percentage of real power dispassion divides by rated power dispassion for power supply unit internal component.
 Thermal curve Curve of temperature be measured from power supply unit component under normal operating.
 Downgrade operating Power supply unit should reduce its output power if ambient temperature exceeds specified range.
 Load curve Curve of power supply unit outputs current capacity and temperature.